23 research outputs found

    Identification and rejection of scattered neutrons in AGATA

    Full text link
    Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were used for a time-of-flight measurement, which gave an independent discrimination of neutrons and gamma rays and which was used to optimise the gamma-ray tracking-based neutron rejection methods. It was found that standard gamma-ray tracking, without any additional neutron rejection features, eliminates effectively most of the interaction points due to recoiling Ge nuclei after elastic scattering of neutrons. Standard tracking rejects also a significant amount of the events due to inelastic scattering of neutrons in the germanium crystals. Further enhancements of the neutron rejection was obtained by setting conditions on the following quantities, which were evaluated for each event by the tracking algorithm: energy of the first and second interaction point, difference in the calculated incoming direction of the gamma ray, figure-of-merit value. The experimental results of tracking with neutron rejection agree rather well with Geant4 simulations

    Discrimination of gamma rays due to inelastic neutron scattering in AGATA

    Full text link
    Possibilities of discriminating neutrons and gamma rays in the AGATA gamma-ray tracking spectrometer have been investigated with the aim of reducing the background due to inelastic scattering of neutrons in the high-purity germanium crystals. This background may become a serious problem especially in experiments with neutron-rich radioactive ion beams. Simulations using the Geant4 toolkit and a tracking program based on the forward tracking algorithm were carried out by emitting neutrons and gamma rays from the center of AGATA. Three different methods were developed and tested in order to find 'fingerprints' of the neutron interaction points in the detectors. In a simulation with simultaneous emission of six neutrons with energies in the range 1-5 MeV and ten gamma rays with energies between 150 and 1450 keV, the peak-to-background ratio at a gamma-ray energy of 1.0 MeV was improved by a factor of 2.4 after neutron rejection with a reduction of the photopeak efficiency at 1.0 MeV of only a factor of 1.25.Comment: Accepted for publication in Nuclear Instruments and Methods in Physics Research, A, 26 May 2009; 13 pages, 5 tables, 12 figure

    Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA

    Get PDF
    The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large (Formula presented.) -ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23l and it is filled with the EJ301 liquid scintillator, that presents good neutron- (Formula presented.) discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the 58Ni + 56Fe reaction measured with the Neutron Wall detector array

    Search for 22^{22}Na in novae supported by a novel method for measuring femtosecond nuclear lifetimes

    Get PDF
    Classical novae are thermonuclear explosions in stellar binary systems, and important sources of 26^{26}Al and 22^{22}Na. While gamma rays from the decay of the former radioisotope have been observed throughout the Galaxy, 22^{22}Na remains untraceable. The half-life of 22^{22}Na (2.6 yr) would allow the observation of its 1.275 MeV gamma-ray line from a cosmic source. However, the prediction of such an observation requires good knowledge of the nuclear reactions involved in the production and destruction of this nucleus. The 22^{22}Na(p,γp,\gamma)23^{23}Mg reaction remains the only source of large uncertainty about the amount of 22^{22}Na ejected. Its rate is dominated by a single resonance on the short-lived state at 7785.0(7) keV in 23^{23}Mg. In the present work, a combined analysis of particle-particle correlations and velocity-difference profiles is proposed to measure femtosecond nuclear lifetimes. The application of this novel method to the study of the 23^{23}Mg states, combining magnetic and highly-segmented tracking gamma-ray spectrometers, places strong limits on the amount of 22^{22}Na produced in novae, explains its non-observation to date in gamma rays (flux < 2.5x10410^{-4} ph/(cm2^2s)), and constrains its detectability with future space-borne observatories.Comment: 18 pages, 3 figures, 1 tabl

    The singular eigenfunction method: The critical slab problem for linearly anisotropic scattering (Rewiew)

    No full text
    The critical slab problem for linearly anisotropic scattering is investigated using the singular eigenfunction method. The third form of the transport equation is considered. The singular eigenfunctions for linearly anisotropic scattering are inserted into the Green's function. This Green's function with the full range orthogonality relations of the singular eigenfunctions together with the appropriate boundary conditions provide the criticality equation. This equation is exact and leads as shown in tables to fast converging numerical results. © Carl Hanser Verlag, München
    corecore